Thermal Bridging Explained: Cold Spots, Mould and How to Fix Them
Thermal bridging is when heat takes a short cut out of your home through a spot where the insulation is broken, thinner or bypassed by a more conductive material, such as a concrete lintel, a steel beam or the junction where a wall meets the floor. These spots run colder than the surfaces around them, which wastes heat and often shows up as black mould lines, damp corners and condensation. You may also hear it called cold bridging, and each individual weak spot is a thermal bridge.
This guide explains where thermal bridges occur in Irish homes, how to spot them, how the Building Regulations deal with them and how good detailing during an upgrade reduces them rather than making them worse.
What is a thermal bridge?
Heat always moves from warm to cold by the easiest route available. In a well-insulated wall, that route is slow. But wherever something more conductive passes through the insulation, or the insulation stops short, heat escapes faster. That weak point is a thermal bridge.
There are two broad types:
- Repeating thermal bridges: elements that occur regularly across a wall or roof, such as timber studs in a frame wall or rafters between roof insulation. These are usually allowed for in the wall or roof’s U-value.
- Non-repeating (linear) thermal bridges: breaks at junctions and openings, such as lintels, window reveals, wall-to-floor and wall-to-roof junctions. These are measured by length and are the ones most people mean when they talk about thermal bridging.
The heat lost through a linear thermal bridge is described by its psi-value (Ψ), measured in watts per metre per degree (W/mK). The lower the psi-value, the better the junction.
Where thermal bridging happens in Irish homes
Most Irish houses built before the 2000s were not designed with junction detailing in mind, so thermal bridges are common. The usual suspects:
Lintels
Concrete or steel lintels over windows and doors span straight across the wall, often bridging the cavity. They are a classic cold spot, especially in cavity-wall houses where the lintel runs from inner leaf to outer leaf.
Window and door reveals
The sides, head and sill of each opening are where the wall’s insulation tends to stop. Where the reveal is solid block or concrete returned to the frame, heat bypasses the insulation. Window position matters too: a frame set well back from the insulation line creates a bigger bridge.
Wall-to-floor junctions
Where the ground floor slab meets the external wall, heat can escape down and out through the foundation. If the floor has some insulation and the wall has some, but the two do not meet, there is a gap all the way around the house.
Wall-to-roof junctions (eaves)
Attic insulation often stops short at the eaves to keep ventilation paths clear, and the wall insulation rarely connects to it. The result is a cold strip along the top of the external walls, which is why mould often appears where the wall meets the ceiling.
Concrete balconies and canopies
A concrete balcony or canopy cast as one piece with the floor slab acts like a cooling fin, drawing heat straight out through the wall. These are common in apartments and some 1970s houses.
Steel beams and columns
Steel conducts heat far more readily than masonry or timber. Steel beams in extensions, around large openings or in knocked-through rear walls are frequent thermal bridges, particularly where they reach the external face.
Party walls and internal walls
Where an internal wall or party wall meets an external wall, the masonry can carry heat out past the insulation, particularly when insulation has only been added on the inside.
Signs you have a thermal bridging problem
- Black mould lines along the junction of the external wall and the ceiling, or the wall and the floor.
- Mould or damp in corners of external walls, especially behind furniture.
- Condensation on window reveals and around the frame, not just on the glass.
- Cold spots you can feel with your hand around lintels, beams or reveals.
- Patterned staining on ceilings that follows joists or the line of a beam.
- Thermal imaging showing cold bands at junctions and around openings.
Mould appears because a cold surface cools the air next to it until moisture condenses. That is why the fix is rarely just a better dehumidifier. If damp and mould are your main concern, read our guides on the best insulation to stop condensation and stopping damp coming through external walls. If the house simply feels cold, our article on why your house is so cold looks at all the likely causes, and our draught-proofing guide covers the air leaks that often sit right alongside thermal bridges.
How the Building Regulations deal with thermal bridging
In Ireland, thermal bridging is addressed in Part L of the Building Regulations through Technical Guidance Document L (Conservation of Fuel and Energy, Dwellings). TGD L requires care to limit heat loss at thermal bridges, and sets out ways to do this. The main ones are:
- Acceptable Construction Details (ACDs): a set of standard junction drawings published by the Department of Housing for common Irish construction types. Each detail comes with psi-values and guidance on continuity of insulation and airtightness.
- Certified details: junctions assessed and certified by a third party, such as NSAI Agrément, in line with Appendix D of TGD L.
- Alternative details: designs shown to limit the risk of mould growth and surface condensation to an acceptable level.
Two numbers are worth knowing:
- The temperature factor (fRsi): TGD L Appendix D sets a minimum of 0.75 for dwellings. In plain terms, the inside surface at a junction should stay warm enough relative to the room and outdoor temperatures that mould and surface condensation are avoided.
- The thermal bridging factor (y-value): used in the BER calculation (DEAP) to account for junction heat loss across the whole house. SEAI’s DEAP guidance applies a default y-value of 0.15 W/m²K to most dwellings, and 0.08 W/m²K to new dwellings built to the Acceptable Construction Details with signed-off drawings. Assessors can also calculate a specific value using psi-values for each junction.
For existing homes, the practical point is this: unless a junction has been designed and recorded, a BER assessor typically uses the default y-value. Good junction detailing during a retrofit can therefore help your BER as well as your comfort.
How insulation upgrades reduce thermal bridging
Insulating from the outside
Wrapping the outside of the house is the most effective way to deal with most thermal bridges in one go. The insulation passes continuously over lintels, the ends of internal and party walls, floor slab edges and beams, so the structure sits on the warm side. The critical details are the window reveals, the base of the wall (carrying insulation down below the floor level where possible) and the eaves, where the wall insulation should meet the attic insulation. See our page on external wall insulation.
Insulating reveals
Reveals are the most commonly skipped detail. Even a thin layer of high-performance insulation returned into the reveal and under the sill makes a measurable difference to surface temperature around the window. If new windows are going in at the same time, setting them forward into the insulation line is better still.
Insulating from the inside
Internal wall insulation works well when detailed properly, but it is the option most likely to create new thermal bridges. That is because every internal wall, floor and ceiling that meets the external wall interrupts the insulation.
Why poorly detailed internal insulation can make things worse
When you insulate the inside face of a wall, the wall itself becomes colder. Wherever the insulation stops (at a floor void, a partition wall, a reveal or behind a kitchen unit), the exposed section of wall is now colder than it was before. Moisture in the room finds those cold spots, and mould can appear in places it never did previously.
Common mistakes we see include:
- Insulation stopping short of reveals, leaving the original cold masonry around every window.
- No return of insulation along the first section of internal walls and ceilings where they meet the external wall.
- Gaps behind boards where air can circulate, so cold air reaches the warm side.
- Missing or broken vapour control, letting warm moist air reach cold surfaces within the wall.
- No improvement to ventilation, so moisture levels rise as the house becomes more airtight.
Done properly, internal insulation includes returns into reveals, careful sealing at junctions and a ventilation plan. Our article on why ventilation is essential after insulating explains why the last point matters as much as the insulation itself.
What to ask before you insulate
- How will the insulation be carried around reveals, sills and heads?
- How does the wall insulation connect with the attic and floor insulation?
- Are there lintels, beams or balconies that need extra treatment?
- What is the plan for ventilation once the house is tighter?
A contractor who can answer those questions clearly is thinking about thermal bridging. If you would like someone to look at the cold spots and mould in your home and explain where the heat is escaping, book a free survey.
Frequently Asked Questions
Is cold bridging the same as thermal bridging?
Yes. Cold bridging and thermal bridging describe the same thing: a weak point in the insulation where heat escapes faster and the inside surface runs colder than the area around it.
Can thermal bridging cause mould?
Yes. A thermal bridge creates a cold patch on the inside surface. Moist room air condenses on that patch, and repeated condensation leads to mould, typically at wall and ceiling junctions, corners and window reveals.
What is a psi-value?
A psi-value (Ψ) measures how much heat is lost along a linear thermal bridge, such as a lintel or wall-to-floor junction, per metre of length and per degree of temperature difference. Lower values mean a better-detailed junction.
Does external wall insulation remove thermal bridges?
It removes or greatly reduces most of them, because the insulation runs continuously over lintels, slab edges and internal wall junctions. Reveals, the base of the wall and the eaves still need careful detailing to finish the job.
Can internal insulation make thermal bridging worse?
It can if it is badly detailed. Insulating the inside of a wall makes the wall colder, so any gaps at reveals, floors or internal walls become colder spots where condensation and mould can form.
Ready to Enhance Your Home’s Energy Efficiency?
Unlock incredible savings and step into a sustainable future with Osber.ie. Our convenient contact form is just a click away. Fill in your details, let us know how we can assist you, and our friendly staff will get back to you promptly, to discuss your construction project according to your goals, or inquire about our services.